Below is a brief description of each ancillary device. For more information, please download the product literature.

6000/SSR Electronic Sounder

The 6000/SSR addressable loop powered high output electronic sounder designed by Protec in house developers, utilises a Piezo driver unit to enable high sound output and very low current consumption. With two base options and improved aesthetic appearance the 6000/SSR simplifies the installation of the device.

Available in either Red or White body colours, the 6000/SSR has an IP65 rating making the product suitable for mounting internally or externally. An optional deep base allows surface mounted cable to be terminated directly into the sounder.

 

Downloads



6000/LED High Intensity Flashing Beacon

The unique Protec 6000/LED utilises a high intensity flashing beacon array. This arrangement simplifies installation and considerably improves the aesthetic appearance compared to the more costly and cumbersome alternatives. The 6000/LED is the latest addition to the range of audio/visual devices offered by Protec.

The 6000/LED is available in a choice of lens and backbox colours and has an IP65 rating making the product suitable for mounting internally or externally.

 

Downloads



6000/SSR/LED Electronic Sounder Beacon

The 6000/SSR/LED comprises a high output electronic sounder and high intensity flashing beacon array. Combining the two functions in one compact design, improves the aesthetic appearance and simplifies the installation of the device.

Available in a choice of lens and body colours, the 6000/SSR/LED has an IP65 rating making the product suitable for mounting internally or externally.

 

Downloads



6000PLUS/TSR2 - Talking Sounder

For the ultimate method of alerting building occupants of the incidence of an emergency, the Protec Algo-Tec™ 6000PLUS/TSR2 is equipped with an integrated voice enhanced sounder. The talking sounder is capable of delivering synchronised alert and evacuate messages around a building, removing any ambiguity, particularly for anyone unfamiliar with the building alert and evacuation strategy, enabling a more prompt and safe building evacuation.
When combined with the LED beacons and multi-sensor fire detection technology, we are able to provide the ultimate and most
innovative fire detection PLUS alarm system for buildings.

 

Downloads



6000PLUS/TSR2/LED - Talking Sounder with LED Beacon

For the ultimate method of alerting building occupants of the incidence of an emergency, the Protec Algo-Tec™ 6000PLUS/TSR2/LED is equipped with an integrated voice enhanced sounder and high intensity flashing beacon array. The talking sounder is capable of delivering synchronised alert and evacuate messages around a building, removing any ambiguity, particularly for anyone unfamiliar with the building alert and evacuation trategy, enabling a more prompt and safe building evacuation.
Combining the talking sounder and beacon functions in one compact design improves the aesthetic appearance and simplifies the installation of the device.

 

Downloads



6000/MCP Manual Call Point

Installation efficiency, flexibility and full compliance with the latest standards are at the heart of the 6000/MCP indoor call point.

Installation time and ultimately cost, are of paramount importance to any fire or security installer. The 6000/MCP range directly reflects this need by providing a unique ‘plug and play’ concept designed specifically to reduce installation time.

 

Downloads



6000/MCP Weatherproof Manual Call Point

Installation efficiency, flexibility and full compliance with the latest standards are at the heart of the the 6000/MCP/WP outdoor call point.

The 6000/MCP/WP is an IP67 sealed manual call point product. The enhanced environmental protection allows the unit to be installed in many external environments where water and dirt are likely to be present, making it a true waterproof and outdoor product.

 

Downloads



6000/MICCO Monitored Input Clean Contact Output Interface

The Protec 6000 series MICCO is a loop powered fault monitored input and a volt free clean contact output interface. An on board isolator is provided which protects against loop short circuits on either the incoming or outgoing loop connections.

 

Downloads



6000/UG4DP, 6000PLUS/UG4DP
Ventiliation Duct Smoke Detector

The duct smoke detector provides early detection of smoke and products of combustion present in air moving through an HVAC duct. The assembly requires 6000/OP or 6000PLUS/OP digital addressable head. The unit has been specially constructed to allow optimum airflow through the smoke detector’s chamber.

A revolutionary ‘one pipe system’, the Venturi Principle, is achieved by the use of a single pipe with two built-in channels which directs the airflow smoothly through the detector’s chamber and returns the air back into the duct. An airflow indicator confirms airflow through the unit itself when the airflow is above 0.75 m/sec.

 

Downloads



6000/FIREBEAM40 Optical Beam Smoke Detector

The Protec Algo-Tec™ 6000/FIREBEAM40 Addressable Loop Powered Reflective Optical Beam Smoke Detector includes a motorised head unit containing an infra-red transmitter and receiver, a ground level controller and prism reflector. Making use of the prism reflector the returned infrared beam is analysed for smoke contamination and registers a fire condition at a pre determined level.

At ground level the controller unit is used to make operational adjustments. The standard unit covers a range of 5 to 40 metres. To increase the beam range additional reflectors are added.We have 2
kits available; FIREBEAM40/80KIT for a range of 40 to 80 metres, and FIREBEAM80/100KIT for a range of 80 to 100 metres.

 