Two-channel Input/Output Interface - 6000/2IO
- 2 x Monitored Detection Zones
- 2 x Monitored Alarm Outputs
- Auxiliary 24vDC Powered
- DIN Rail Mounted
- Integral Short Circuit Isolator
Product Details
Our 6000/2IO is a loop-powered input/output device providing two individually monitored inputs and two volt-free changeover contacts, best used to connect ancillary equipment to a Protec fire alarm system.
Protec advanced addressable fire alarm systems are equipped with a wide range of interfaces that can effortlessly and efficiently integrate third-party systems. Our cutting edge 6000PLUS protocol is used for comprehensive system monitoring, ensuring that in the event of an emergency, third-party systems such as gas, plant machinery, lifts, Automatic Opening Vents (AOV’s), etc., are promptly activated or shut down to minimise damage and ensure the safety of the building and its occupants.
To make the commissioning process simple, we have incorporated our FAST™ commissioning method and equipped the interface range with an inbuilt loop short circuit isolator to enhance reliability and safety. Our fire alarm system continuously monitors our interfaces to ensure maximum protection for the building and its occupants.
| Product Code | 6000/2IO |
| Environment | -10°C to +50°C (95% R.H. non condensing) |
| Ingress Protection | IP00 |
| Weight | 245g (including din rail housing, no backbox, 4 way build) |
| Din Rail Mounted | Yes |
| Inputs | 2 x Monitored Inputs |
| Outputs | 2 x Clean Contact Outputs |
| Isolator | Yes, on board (consult Protec DEL2110 for details) |
| Compatible Panels | 6500, 6100, 6400, 6300 |
| Number of Loop Addresses Used | 2 maximum, user and build configurable |
| Loop Alarm Current (Average) | 18mA |
| Loop Alarm Current (Peak) | n/a |
| Loop Protocol | 6000/6000PLUS |
| Loop Powered | Yes |
| Loop Voltage Range | 18 V dc – 28 V dc peak loop |
| Loop Quiescent Current (24V Loop Peak) | 1.6 mA + zone end of line current + zone loading |
| Zone Quiescent Current | n/a |
| Zone Reset Time | n/a |
| Max Number of Detectors | n/a |
| Detectors Supported | n/a |
| Sounders Supported | n/a |
| Clean Contact Output Details | 1 Single pole changeover rated for 2 A maximum at 24 V dc (non inductive) 1 Single pole changeover rated for 8 A maximum at 24 V ac (non inductive) |
| Dimensions (mm) | 146.5(W) x 39(H) x 118(D) |
| Technical Documentation | DEL2118 |
Technical documents such as Manuals, Software downloads, BIM families, and more are available via our Client / Support Portal. To access, please Sign up or Login to your account.
Sign up or login to your accountRelated Products


- 2 Channel Input/Output InterfaceView Product
- 4 Channel Input/Output InterfaceView Product
- 2 Channel Loop Powered Zone Alarm InterfaceView Product
- Single Channel Auxiliary Powered Zone Alarm InterfaceView Product
- Single Channel Loop Powered Zone Alarm InterfaceView Product